Wednesday, September 30, 2009
Waves, BIG Waves and Outage Explanation
Wednesday, September 16, 2009
Cloud Computing Analysis From Irving Wladawsky-Berger
Wednesday, September 09, 2009
Data Centre Stock Index Launched
Thursday, September 03, 2009
The Internet turns 40
Wednesday, September 02, 2009
Raytheon Acquires BBN Technologies
BBN was acquired by GTE in 1997 and BBN's ISP division BBN Planet was joined with GTE's national fiber network to became GTE Internetworking, "powered by BBN". When GTE and Bell Atlantic merged to become Verizon in 2000, the ISP portion of BBN was included in assets spun off as Genuity. In March 2004, Verizon sold BBN to a group of private investors. In September 2009 Raytheon entered into an agreement to acquire BBN
Following the acquisition, BBN Technologies will become part of Raytheon Network Centric Systems.
I had not been to the BBN web site in quite some time ; upon browsing, they have some pretty amazing research projects listed:
- Flexible Intra-autonomous-system Routing Environment
- Smart Environment for Network Control, Monitoring and Management
- Density-and Asymmetry-aware wireless Networking
- Proprietary waveforms for wireless networks
- Terabit router traffic engineering
DARPA's Quantum Entanglement Science and Technology (QuEST) program is creating new quantum information science technologies, focusing on loss of information due to quantum decoherence, limited communication distance due to signal attenuation, protocols, and larger numbers of quantum bits (Qubits) and their entanglement. Key among the program's challenges is integrating improved single- and entangled-photon and electron sources and detectors into quantum computation and communication networks. Defense applications include highly secure communications, algorithms for optimization in logistics, highly precise measurements of time and position on the earth and in space, and new image and signal processing methods for target tracking.
Tuesday, August 25, 2009
Green Storage, Smart Grids, and Wireless Spectrum for Utility Providers
Monday, August 24, 2009
Data Center Stock Index Update
Monday, August 10, 2009
Smart Grids, City 2.0 and Project Netal
Saturday, August 08, 2009
Now With 20% More Fiber!
Thursday, August 06, 2009
DOE Smart Grid Report and $57 Million Funding
- The Smart Grid: An Introduction
- Smart Grid E-Forums
- Federal Smart Grid Task Force
- Grid 2030 Vision
- Modern Grid Strategy - a project of the National Energy Technology Laboratory
Sunday, July 26, 2009
NASA's Nebula a Possible Federal Cloud Prototype
"Obama's fiscal 2010 budget proposal envisions optimizing cloud computing by "scaling pilots to full capabilities and providing financial support to accelerate migration," the budget stated. The fiscal plan acknowledges the effort will involve upfront costs, but the expense should be more than offset by savings from consolidating data centers."
Check out the nextgov.com article here.
Tuesday, July 21, 2009
Emerson St. Louis Data Center

Some quick specs from this impressive facility include:
35,000 square foot --- 12,000 sq. ft. raised floor and ultimately capacity for 5,000 servers
Anticipating a LEED Gold certification
7,800 square foot Solar array on the roof providing 100kW of power to the IT Load
Applied all 10 attributes of their own Energy Logic road map.
Designed to cope with a variety of natural and man-made disasters (earthquakes, tornadoes, flooding, fires and telecom fiber cuts). The facility was built to withstand up to a F3 tornado or an earthquake up to 8.0 on the Richter scale.
Integrates numerous Emerson Network Power products – including Alber, Aperture, ASCO, Knurr and Liebert.
2 Caterpillar generators, with the capability to add 2 more.
72 hours of fuel on-site plus room to place an additional fuel tank.
Mostly new IT equipment populating the cabinets: Cisco, Dell, EMC and Sun.
Three layers of redundancy:
a. Dual utility feeds (separate physical paths into the building)
b. A and B side mechanical rooms / redundant UPS
c. N+1 Caterpillar generators
In Uptime Institute tier standards it comes about as close as you can to a tier IV data center. Dual-everything inside the building is used to the extent of having A & B telcom rooms where visiting technicians do not have to enter the data center or mechanical rooms to work on carrier equipment. There was great detail paid to the layout of the facility to ensure a separation of IT and facilities staff.
The LEED certification and renewable energy aspect to the facility was impressive. St. Louis based Fox Architects led a multi-disciplinary design and engineering team through years of
planning and 18 months of construction. Fox Architects also led the Monsanto data center project from a few years back. The solar array on the roof gives the ability to (manually) provide 100kW of DC power, directly to the IT load below. They use a Solectria Renewables Grid Tiered Photovoltaic inverter and boast that it is the largest solar array in the state of Missouri. The facility was originally planned to achieve silver LEED certification, but several items gave them additional points, such as approximately 80% of the waste generated during the construction has been diverted from landfills.
Site selection (to me) was a no-brainer, but primary reasons listed by Emerson were low power rates (typically 3-5 cents per kWh), low natural disaster risk, and low telecommunication rates. The sister site Emerson has in Marshalltown Iowa serves as a disaster recovery site and (now) vice versa.
As expected all of the latest and greatest Emerson products were used inside the facility.

Emerson even makes a component inside the Caterpillar generators used. There was amazing use and integration with their Site Scan and Aperture Vista products. A lobby television displays an interactive one-line diagram of their power infrastructure that can also be viewed on their internal corporate network. Site Scan is the dashboard for viewing a wide variety of data on the facility, load, IT equipment and other critical components. Emerson also incorporated the strategies and technologies advocated in their Energy Logic roadmap for improving efficiency. For instance they used a 240 volt power distribution architecture instead of the typical 208V. Aperture Vista is used for facility operations and future planning.
The “Liebert Adaptive Architecture” was seen in action throughout the facility:
1. Liebert DS precision cooling system
2. Liebert NXL on-line UPS
3. Liebert XD Cooling module (used when they had blades or higher density in a cabinet)
4. The web based monitoring of Site Scan
5. Liebert FDC power distribution cabinet
6. Liebert MPX adaptive rack PDU. This was just pretty darn cool. The word ‘adaptive’ is key here. It’s modular, re-configurable, supports NEMA and IEC, has SNMP and a host of other metrics and monitoring capabilities. The product is not yet released, but I was able to find this German Knurr brief on it – here.
The IT equipment going in to phase 1 of this facility will include around 400 servers plus storage and network gear. They intend to use blade systems (Sun I assume) and have approximately a 15:1 virtualization ratio. All network distribution to the cabinets is fiber. Following the dual-everything approach, each cabinet is fed A and B side fiber runs and there is NO copper in the under-floor trays. The 3 foot raised floor serves all electrical connectivity, cable trays for communication and FM200 protection.
The FM200 distribution under-floor was interesting to me. With so much going on under the floor the thought was to put out the fire in this 3 foot raised area, but not above floor for the IT equipment. Above floor fire protection comes in the form of pre-action dry pipe. This is also then used in power equipment rooms that are on slab.
Designed to be a lights-out facility, the on-site staff may just achieve that if they sit still too long and the motion-detection lights shut off. J CNN was playing on the TV in the lobby, which means cable, which means the St. Louis Cardinals SURELY are on whenever the boss isn’t around.
Sunday, July 19, 2009
New Paetec Data Center
"The 6,500 square feet of space available for customers includes the newest advancements in equipment with connectivity up to 10 Gbps, more energy efficient devices, higher cooling capacity to meet the increasingly powerful applications and a new Bi-Fuel power system providing redundant power generation fueled by conventional diesel, or a cleaner combination of diesel and natural gas. The center is also served by a diverse power grid, separate from New York City and Philadelphia, offering further resiliency in the event of a wide-scale brown-out or power outage in the area."The press release mentiones Paetec's data center solutions -- at fast.net ; but I am unable to get a web page to resolve at that address. According to archive.org the fast.net site dropped off in late 2007. More information on hosting/colocation off of the Paetec web site can be found here.
Wednesday, July 15, 2009
Renewable Energy Roundup

I've run across several items recently of interest in terms of smartgrids, new energy sources and reports on renewable energy.
Wednesday, July 08, 2009
Superb Intnernet Hosting - New Virginia Data Center
SGI/Rackable ICECube Deployment Video
Monday, July 06, 2009
The Greenest Supercomputer

Performance efficiency, or “LINPACK efficiency,” measures the ratio between maximum performance (RMax) and peak performance (RPeak). SGI dominated this new category with 12 of the 20 most performance-efficient supercomputers in the world."
"The features of the expanded Rackable x86 server lines include dual QSFP InfiniBand/Ethernet ports at up to 40 Gb/s (gigabits-per-second), Intel Xeon 5500 series "Nehalem" processors, including the top-bin W5580 running at 3.2 GHz, and large memory capability with up to 96 GB (gigabytes) of ECC registered DDR3 DIMMs. It is also power optimized with over 90 percent voltage regulator module efficiency on the server board, which perfectly complements SGI’s up-to-96.5 percent-efficient power supplies."
Sunday, July 05, 2009
Tech Industry M&A Activity
Tuesday, June 30, 2009
CoreSite Prepares 20,000 sq. ft In Their Chicago Data Center
Equinix Wins Engergy Innovator Award
"As a part of Equinix’s expansion at its SV2 center, the company implemented a variety of efficient procedures, such as installing air-side economizers that use the outside air to provide “free cooling” and drastically reduce the amount of mechanically produced cold air needed for the center. This system has resulted in energy savings of more than 4,000,000 kWh and $300,000 per year. Equinix also installed variable frequency drive (VFD) fans that allow for greater efficiency by operating at reduced fan speeds when there is a lower demand for air distribution."